涓枃

English


CATEGORY




Contact Us  
TEL:+86 755 23225716
EMAIL:info@hkyouzi.com
Skype:hkyouzi
ADD:HuaChuangDa,LongQuan 1 Road,BaoAn 38 District锛孲henZhen,GuangDong,China



HUAWEI_ME60-X8_Router

Huawei ME60-X8 with 1*Chassis, 2*SRUA570 200G switch and route processing board, 1*SFU 200G switching board,DC power module

Description

ME60-X8  Overview

ME60 series are multiple-service control gateways (BRASs) developed by Huawei for industries such as broadcasting, television, and education. ME60s provide a platform for unified user access and management.

Based on a 2T platform, ME60s provide the industry鈥檚 largest-capacity routing line card (480G) and a large-capacity NAT service line card (160G) that enable customers to smoothly evolve from IPv4 to IPv6.

Table 1 Basic information about the ME60-X8

DescriptionPart NumberModelFirst Supported VersionRemarks
ME60-X8 Integrated Chassis Components (Including 4 DC Power)02352021ME0B0BKP0830V800R008C10

 

ME60-X8 Appearance and Components

Figure 1 Appearance of Huawei ME60-X8


Huawei routes ME60

 ME60-X8-1

Figure 2 Components

ME60-X8


Huawei routes ME60

 

1. Air intake vent2. SRU3. SFU4. BSU/MSU
5. Cable tray6. Fan7. Filler Panel8. Ground terminal
9. Rear cable trough10. Power management interface11. DC power module12. Handle
13. Central monitoring module (Optional)14. Mounting ear

 

Technical Specifications

ItemSpecification
Cabinet installation standardsCan be installed in a standard 19鈥 800 mm-deep cabinet. A Huawei 2.2 m-high N68E cabinet is used by default.
Dimensions without packaging (H x W x D) [mm(in.)]620 mm x 442 mm x 650 mm (24.41 in. x 17.40 in. x 25.59 in.)(Chassis main body)

620 mm x 442 mm x 770 mm (24.41 in. x 17.40 in. x 30.31 in.)(Dimensions of the chassis body together with cable trays and front and back attachments)

Chassis height [U]14 U
Weight without packaging (base configuration) [kg(lb)]43.2 kg (95.26 lb)
Weight without packaging (full configuration) [kg(lb)]136 kg (299.88 lb)
Typical power consumption [W]3220 W (fully configured with BSUF-240s)
Typical heat dissipation [BTU/hour]10447 BTU/hour (fully configured with BSUF-240s)
MTBF [year]33.89 year
MTTR [hour]0.5 hour
Availability0.999998316
Power supply modeDC built-in
Maximum number of power chassis inputs(1 channel/PEM)*4 PEM=4 channels
Rated input voltage [V]鈥48 V/ 鈥60 V
Input voltage range [V]鈥38.4 V to 鈥72 V
Maximum input current [A]70 A/module
Maximum input cable diameter [mm²]35 mm²/channel
Front-end circuit breaker/fuse [A]70 A
Noise at normal temperature (acoustic power) [dB(A)]NEBS-compliance (< 78 dBA @ 27掳C (80.6掳F))
Number of slots11
Number of service board slots8
Switching capacity7.08Tbps(BSUF-240)
Redundant MPUs1:1
Redundant Switch fabrics2+1
Redundant power supply2+2
Redundant fans2 assemblies

Support for proper fan operation in case of a single fan failure for a short period at 40掳C (104掳F)

Long-term operating temperature [掳C(掳F)]0掳C to 45掳C (32掳F to 113掳F)
Short-term operating temperature [掳C(掳F)]-5掳C to 55掳C (23掳F to 131掳F)
Restriction on the operating temperature variation rate [掳C(掳F)]鈮 30掳C/hour (86掳F/hour)
Storage temperature [掳C(掳F)]-40掳C to 70掳C (-40掳F to 158掳F)
Long-term operating relative humidity [RH]5% RH to 85% RH, non-condensing
Short-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Storage relative humidity [RH]5% RH to 95% RH, non-condensing
Long-term operating altitude [m(ft.)]鈮 4000 m (13123.2 ft.) (For the altitude in the range of 1800 m to 4000 m [5905.44 ft. to 13123.2 ft.], the operating temperature of the device must decrease by 1掳C [1.8掳F] for every 220 m [721.78 ft.].)
Storage altitude [m(ft.)]Less than 5000 m (16404 ft.)

Product Features

 

Back


Our Partners
              

Copyright ©2005-2024  Youzi Electronic CO., Limited   All rights reserved     
Tel:86 755 23225716   Email:info@hkyouzi.com

ICP:05000116